Home Page > Valvole di Sicurezza a Scarico Convogliato > G25
G25
G25 - Peso Kg. 3,38
| Tipo : Type : | G25 | do: 25mm | |
|---|---|---|---|
| Omologazione Homologation | PN | Coefficiente efflusso ridotto Low flow coefficient | Campo di taratura Setting range |
| E.D. 2014/68/EU IV Cat.(PED) | 60 | 0,78 | 0,3 - 60,0 bar |
| EAC | 60 | 0,78 | 0,3 - 60,0 bar |
| ATEX Ex II 2 G c | 60 | 0,78 | 0,3 - 60,0 bar |
| ATEX Ex II 2 D c (1) | 60 | 0,78 | 0,3 - 60,0 bar |
| ASME VIII Div.1 | 40 | 0,629 | 1,0 - 30,0 bar |
| Canadian Reg. CRN | 40 | 0,629 | 1,0 - 30,0 bar |
| CONFIGURAZIONE - CONFIGURATION | |||
| Materiale Material |
Ottone Brass |
Mista Ottone-Acciaio inox Mixed Brass-Stainless steel |
Acciaio inox Stainless steel |
| Modelli Model |
Con ghiera | Con ghiera | Con ghiera |
| With ring nut | With ring nut | With ring nut | |
| Senza Ghiera | Senza Ghiera | Senza Ghiera | |
| Without ring nut | Without ring nut | Without ring nut | |
| Con leva | Con leva | Con leva | |
| With lever | With lever | With lever | |
| / | / | Con apertura pneumatica | |
| / | / | With pneumatic opening | |
| / | / | Pneumatica con sensore | |
| / | / | Pneumatic with sensor | |
| Sedi di Tenuta Seal System |
N.B.R. (Std) -10 / + 100 °C | N.B.R. (Std) -10 / + 100 °C | N.B.R. (Std) -10 / + 100 °C |
| E.P.D.M. -50 / + 150 °C | E.P.D.M. -50 / + 150 °C | E.P.D.M. -50 / + 150 °C | |
| VITON -20 / +200 °C | VITON -20 / +200 °C | VITON -20 / +200 °C | |
| SILICONE -60 / +200 °C | SILICONE -60 / +200 °C | SILICONE -60 / +200 °C | |
| TEFLON -196 / +250 °C | TEFLON -196 / +250 °C | TEFLON -196 / +250 °C | |
| KALREZ -20 / +250 °C | KALREZ -20 / +250 °C | KALREZ -20 / +275 °C | |
| / | Metal -196 / +250 °C | Metal -196 / +450 °C | |
| Connessione Entrata Inlet Connection |
G.1"1/4 - 1"1/2 ISO228 | G.1"1/4 - 1"1/2 ISO228 | G.1"1/4 - 1"1/2 ISO228 |
| R.1"1/4 - 1"1/2 EN10226 | R.1"1/4 - 1"1/2 EN10226 | R.1"1/4 - 1"1/2 EN10226 | |
| 1"1/4 - 1"1/2 NPT | 1"1/4 - 1"1/2 NPT | 1"1/4 - 1"1/2 NPT | |
| DN32-40 PN16-40-60 | 1"1/2 Tri Clamp | 1"1/2 Tri Clamp | |
| 1"1/4 - 1"1/2 150-300 lb | DN25-32-40 DIN405-11851 | DN25-32-40 DIN405-11851 | |
| / | DN32-50 PN16-40-60 | DN32-50 PN16-40-60 | |
| / | 1"1/4 - 2" 150-300 lb | 1"1/4 - 2" 150-300 lb | |
| Connessione Uscita Outlet Connection |
G.1"1/2 ISO228 | G.1"1/2 ISO228 | G.1"1/2 ISO228 |
| DN40-50 PN16-40-60 | 1"1/2 Tri Clamp | 1"1/2 Tri Clamp | |
| 1"1/2 - 2" 150-300 lb | DN32-40 DIN405-11851 | DN32-40 DIN405-11851 | |
| / | DN40-50 PN16-40-60 | DN40-50 PN16-40-60 | |
| / | 1"1/2 - 2" 150-300 lb | 1"1/2 - 2" 150-300 lb | |
| / | / | / | |
| / | / | / | |
| A richiesta possono essere eseguiti collaudi dai più prestigiosi enti quali: INAIL (area ISPESL), TÜV, RINA, Bureau Veritas, ABS e Lloyd On request tests can be made by the most prestigious societies, such as: INAIL (area ISPELS), TÜV, RINA, Bureau Veritas, ABS and Lloyd Register. |
|||
| Note: (1) No Modello Con leva / No Model With lever | |||